Showing results: 46 - 60 of 410 items found.
-
KVIO-80 -
KV Hipot Power Test Equipment Co.,Ltd
Automatic Insulation Oil Breakdown Tester Is Used to carry on power frequency dielectric break down test on the transformer oil, capacitor oil, electric device, insulation tool etc.
-
M191 -
MEATEST, s.r.o.
High resistance calibrator for insulation testers up to 10 kV. Other insulation related functions include HV capacitance, short current, dielectric and polarization parameters and timer test.
-
Model KM 877 -
Kusam Electrical Industries Limited
• VFD V & Hz readings.• Paper White Backlight LCD Display• Record MAX / MIN readings.• Display Hold Function.• Dual Digital Display.• PI & DAR Function.• Autoranging.• Pass /Fail Insulation Resistance Compare function; 12 selectable Preset Values.• LOCK-Test mode for Insulation Resistance & Earth Continuity Test.• BeepJack ™ audible & visible input warning.• Remote Probe for insulation Resistance & Earth Continuity Test.• Functions : DC/AC Voltage , VFD AC Voltage, Insulation Resisitance, Resistance, Earth Continuity Test, Hz Line Level Frequency
-
AMIC-30 -
Amperis sl
The AMIC-30 insulation tester is a small portable meter designed to measure insulation resistance in electrical and telecommunications installations, cables, motors, transformers and other equipment. The test voltage can be programmed in steps from 10 V to 1000 V. The instrument can measure both insulation resistance over a wide range (0,1kΩ...100GΩ), and insulation leakage current, capacitance and other parameters. All test results can be stored in the internal memory and sent to a computer via the included wireless USB receiver. The meters are supplied with rechargeable Ni-Cd batteries.
-
-
Megger Group Ltd.
Diagnostic insulation testing today represents over a hundred years of constant development. When Sydney Evershed pioneered the first insulation tests in the late 19th century, the only measurable values were insulation at 500 volts and a basic continuity check. However, measurement techniques have continuously evolved to keep pace with new insulation technologies. From electronic design and household wiring to generators and power transmission systems, all different kinds of insulation must operate at a safe minimum value.
-
HopeTech
insulation resistance tester is an instrument for measuring the insulation resistance of components and equipment. Using constant voltage test method, the voltage output range is 25 ~ 1000V, and the maximum output current is 1.8mA. It also has contact anomaly detection function and short circuit anomaly test function, the fastest test time is up to 50mS.
-
1507 -
Fluke Corporation
The Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications.
-
Sanwa Electric Instrument Co., Ltd
Is a spot insulation test which uses an applied DC voltage (typically either 250Vdc, 500Vdc or 1,000Vdc for low voltage equipment <600V and 2,500Vdc and 5,000Vdc for high voltage equipment) to measure insulation resistance.
-
LXinstruments GmbH
The hipot test (high potential test) or dielectric withstand test, is used to determine the insulation and dielectric strength. It is carried out on modules, devices and systems of protection class I + II. In this test, the insulation of the test object is subjected to greater stress by the high voltage than in normal operation. It is determined whether the insulation of all current-carrying conductors, as well as the safety distance to the enclosure, is sufficient and complies with the legal requirements under normal operating conditions.We will be happy to assist you with any questions or solutions to problems.You will find a large selection of high-voltage testers in our comprehensive shop.Questions? We are always at your disposal.
-
8010 IN -
Standard Electric Works Co., Ltd
● Microprocessor controlled.● Four insulation test voltages (DC) : 125V, 250V, 500V, 1000V● The maximum insulation measurement range is 200G ohm @1000V.● 1mA test current on insulation test at nominal voltage.● With a hand strap for easier holding.● Large LCD (78 × 67mm)● Auto-ranging.● Bar-graph indication.● Backlight function.● REL(Auto-null) function.● Auto AC/DC voltmeter.● Capacitor test.● Auto-test stop & smart hold.● Supplied with high quality test leads.● Safety standard : EN 61010-1 CAT III 600V IEC 61557-1 IEC 61557-2 EN 61326-1
-
Model FT1 -
Gopal Electronics
The Franklin tester FT‐1 is designed to measure the surface insulation resistivity of electrical steel sheet according to the ASTM Standard A717 and IS:649. This test method is suitable for quality control in the application of insulation coating. For ease of testing FT‐1 automatically set 300 PSI pressure on the sample by the inbuilt hydraulic unit and it is capable to set the desired test temperature of the platform. Then the regulated supply of 0.5V gets on and the current flowing through the insulation get measured. The calculated insulation resistivity will be displayed on graphics LCD display and as well as on printed report via thermal printer.
-
-
-
2151 IN -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 68 × 34mm(2.677” × 1.338”) large LCD display.● 3½ digital LCD(2000 counts) a LCD indicated instrument for insulation.(MΩ), continuity(Ω) and AC voltage.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA DC load.● >200mA short circuit testing current for a resistance tests.● Auto ranging.● REL function.● Auto power OFF.● Fuse protection.● Auto data hold.● BS 16 edition.